Panel Performance
|
Fire
Surface spread of flames
Class 1 tested in accordance with BS 476 part 7 1971.
Sprinklers: Provided
F.O.C. rules are observed all TECH panels can be used in conjunction
with ceiling cavity located sprinklers as their open area exceeds
70%
|
 |
 |
Humidity
TECH panels must not
be exposed to humidity levels in excess of 75% R.H. However moisture
resistant MDF 313 has been tested with success for use to 85% R.H.
but no performance guarantees are available.
|
Durability
Lightweight but strong,
TECH panels are expected to last for the life of the building under
normal conditions and subject to reasonable handling
|
 |
 |
Handling and Storage
TECH panels are packed
10 to a carton (3.6 sqm) and should be stored in dry conditions
off the ground with good air circulation around. Cartons should
be stacked to a maximum 6 high and should be stored on the site
at least 6 days in the same maintained environment as the occupied
building.
|